using System;
using System.Collections.Generic;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
namespace IStation.Calculation
{
internal class shys陈行一输 : PlanAnaBaseCalculator
{
public shys陈行一输()
{
this._corpID = 4;
this._dispatchAnaCalc = new IStation.Calculation.DispatchAna.Calculator_OptAna_SHYS_陈行一输();
}
///
/// 测点字典(这个每个泵站都不一样)
///
private Tuple monitor出水总管1压力 = new Tuple("_0402010201090105001",
IStation.Calculation.DispatchAna.Calculator_OptAna_SHYS_陈行一输._monitor_id_一号管压力);
private Tuple monitor出水总管1瞬时流量 = new Tuple("_0402060601010103000",
IStation.Calculation.DispatchAna.Calculator_OptAna_SHYS_陈行一输._monitor_id_一号管流量);
private Tuple monitor出水总管2压力 = new Tuple("_0402010201090105002",
IStation.Calculation.DispatchAna.Calculator_OptAna_SHYS_陈行一输._monitor_id_二号管压力);
private Tuple monitor出水总管2瞬时流量 = new Tuple("_0402060601010203000",
IStation.Calculation.DispatchAna.Calculator_OptAna_SHYS_陈行一输._monitor_id_二号管流量);
private Tuple monitor出水总管3压力 = new Tuple("_0402060601010305000",
IStation.Calculation.DispatchAna.Calculator_OptAna_SHYS_陈行一输._monitor_id_三号管压力);
//private Tuple monitor出水总管3瞬时流量 = new Tuple("_0402010503030202003",
private Tuple monitor出水总管3瞬时流量 = new Tuple("_0402060601010306000",
IStation.Calculation.DispatchAna.Calculator_OptAna_SHYS_陈行一输._monitor_id_三号管流量);
private Tuple monitor进水前池液位1 = new Tuple("_0402010201090104011",
IStation.Calculation.DispatchAna.Calculator_OptAna_SHYS_陈行一输._monitor_id_液位1);
private Tuple monitor进水前池液位2 = new Tuple("_0402010201091104123",
IStation.Calculation.DispatchAna.Calculator_OptAna_SHYS_陈行一输._monitor_id_液位2);
private Tuple monitor进水前池液位3 = new Tuple("_0402010201091104122",
IStation.Calculation.DispatchAna.Calculator_OptAna_SHYS_陈行一输._monitor_id_液位3);
public override bool Is液位Monitor(string tagname)
{
if (monitor进水前池液位1.Item1 == tagname)
return true;
if (monitor进水前池液位2.Item1 == tagname)
return true;
if (monitor进水前池液位3.Item1 == tagname)
return true;
return false;
}
public override string GetMonitorNameByTag(string tagname)
{
if (monitor出水总管1压力.Item1 == tagname)
return "出水总管1压力";
if (monitor出水总管1瞬时流量.Item1 == tagname)
return "出水总管1瞬时流量";
if (monitor出水总管2压力.Item1 == tagname)
return "出水总管2压力";
if (monitor出水总管2瞬时流量.Item1 == tagname)
return "出水总管2瞬时流量";
if (monitor出水总管3压力.Item1 == tagname)
return "出水总管3压力";
if (monitor出水总管3瞬时流量.Item1 == tagname)
return "出水总管3瞬时流量";
if (monitor进水前池液位1.Item1 == tagname)
return "进水前池液位1";
if (monitor进水前池液位2.Item1 == tagname)
return "进水前池液位2";
if (monitor进水前池液位3.Item1 == tagname)
return "进水前池液位3";
return "未知测点";
}
///
/// 根据三高提供的参数,构建调度分析所需的参数, (这个每个泵站都不一样)
///
///
///
///
protected override DispatchAna.Model.RequestParasComplex BuildDispatchAnaRequest(
List allRecords_hour,
out string error_info)
{
if (allRecords_hour == null || allRecords_hour.Count == 0)
{
error_info = "陈行一输测点数据为空";
return null;
}
var complex_dispatch_request = new DispatchAna.Model.RequestParasComplex();
var water_level1 = allRecords_hour.Find(x => x.MonitorTag == monitor进水前池液位1.Item1);
if (water_level1 == null)
{
error_info = "陈行一输水库液位1测点未找到";
return null;
}
var water_level2 = allRecords_hour.Find(x => x.MonitorTag == monitor进水前池液位2.Item1);
if (water_level2 == null)
{
error_info = "陈行一输水库液位2测点未找到";
return null;
}
var water_level3 = allRecords_hour.Find(x => x.MonitorTag == monitor进水前池液位3.Item1);
if (water_level3 == null)
{
error_info = "陈行一输水库液位3测点未找到";
return null;
}
var pipe1_flow = allRecords_hour.Find(x => x.MonitorTag == monitor出水总管1瞬时流量.Item1);
if (pipe1_flow == null)
{
error_info = "陈行一输水管道1流量测点未找到";
return null;
}
var pipe1_press = allRecords_hour.Find(x => x.MonitorTag == monitor出水总管1压力.Item1);
if (pipe1_press == null)
{
error_info = "陈行一输水管道1压力测点未找到";
return null;
}
var pipe2_flow = allRecords_hour.Find(x => x.MonitorTag == monitor出水总管2瞬时流量.Item1);
if (pipe2_flow == null)
{
error_info = "陈行一输水管道2流量测点未找到";
return null;
}
var pipe2_press = allRecords_hour.Find(x => x.MonitorTag == monitor出水总管2压力.Item1);
if (pipe2_press == null)
{
error_info = "陈行一输水管道2压力测点未找到";
return null;
}
var pipe3_flow = allRecords_hour.Find(x => x.MonitorTag == monitor出水总管3瞬时流量.Item1);
if (pipe3_flow == null)
{
error_info = "陈行一输水管道3流量测点未找到";
return null;
}
var pipe3_press = allRecords_hour.Find(x => x.MonitorTag == monitor出水总管3压力.Item1);
if (pipe3_press == null)
{
error_info = "陈行一输水管道3压力测点未找到";
return null;
}
complex_dispatch_request.CorpID = this._corpID;
complex_dispatch_request.StationID = this._stationID;
complex_dispatch_request.SchemeNumber = 1;
complex_dispatch_request.PressValueType = DispatchAna.Model.RequestParasComplex.ePressValueType.压力;
complex_dispatch_request.InletPipePara = new List()
{
new DispatchAna.Model.InletPipePara(){ Name="液位1", Value = water_level1.RecordValue},
new DispatchAna.Model.InletPipePara(){ Name="液位2", Value = water_level2.RecordValue},
new DispatchAna.Model.InletPipePara(){ Name="液位3", Value = water_level3.RecordValue}
};
complex_dispatch_request.OutletPipePara = new List();
complex_dispatch_request.OutletPipePara.Add(new DispatchAna.Model.OutletPipePara()
{
Name = "管路1",
TargetFlow = pipe1_flow.RecordValue,
TargetPress = pipe1_press.RecordValue,
});
complex_dispatch_request.OutletPipePara.Add(new DispatchAna.Model.OutletPipePara()
{
Name = "管路2",
TargetFlow = pipe2_flow.RecordValue,
TargetPress = pipe2_press.RecordValue,
});
complex_dispatch_request.OutletPipePara.Add(new DispatchAna.Model.OutletPipePara()
{
Name = "管路3",
TargetFlow = pipe3_flow.RecordValue,
TargetPress = pipe3_press.RecordValue,
});
error_info = null;
return complex_dispatch_request;
}
}
}