using IStation.Model;
using System;
using System.Collections.Generic;
using System.Linq;
namespace IStation.EtaCalculation.SHYS.Station
{
///
/// 所有泵, 有 出口压力计, 有开机状态测点, 没有独立的流量计 , 只有管路的流量计,
/// 所有阀门都是打开状态
///
public class EtaAnalyCalculator4陈行一输 : EtaAnalyCalculator泵站4共用多个流量计_有运行状态, IEtaStationAnalyCalculator
{
///
///
///
///
///
///
public override bool Calculate(EtaStationAnalyContextItem context, out string error_info)
{
if (context == null)
{
error_info = "上下文参数为空";
return false ;
}
this._stationID = context.ID;
this._threshold_flow = 100;//高于此值, 认为对应阀门开启, 防止零点飘流
//初始化测点
if (!InitialMonitorList(context, out error_info))
{
return false;
}
//初始化机泵
if (!InitialPumpList(context ,out error_info))
{
return false;
}
//初始化管路
var monitor_id_total_flow_list = new long[] { 860, 863, 866 };
var pipe_id_total_flow_list = new long[] { 759 ,761,768};
if (!InitialPipeList(
pipe_id_total_flow_list,
monitor_id_total_flow_list,
context, out error_info))
{
return false;
}
return base.CalculateCore(context, out error_info);
}
#region 初始化机泵
///
///
///
///
///
///
protected override bool InitialPumpList(Model.EtaStationAnalyContextItem context, out string error_info)
{
long[] monitor_id_pump_flow_array = new long[] { 0, 0, 0, 0, 0, 0, 0, 0 };//单泵流量计
long[] monitor_id_inlet_press_array = new long[] { 856, 856, 856, 857, 857, 858, 858, 858 };// 泵的进口压力计(液位)
long[] monitor_id_outlet_press_array = new long[] { 869, 875, 881, 887, 893, 898, 903, 909 };//出口压力
long[] monitor_id_run_status_array = new long[] { 868, 874, 880, 886, 892, 897, 902, 908 };//运行状态
long[] monitor_id_motor_frequence_array = new long[] { 870, 876, 882, 888, 0, 0, 904, 910 };//频率
long[] monitor_id_motor_power_array = new long[] { 872, 878, 884, 890, 895, 900, 906, 912 };//瞬间功率
long[] monitor_id_motor_zhuansu_array = new long[] { 871, 877, 883, 889, 894, 899, 905, 911 };//转速
long[] machine_id_array = new long[] { 262, 265, 268, 271, 259, 274, 277, 280 };//(5,6 工频)
this._machineCount = 8;
var is液位代替进口压力 = true;
this._allMachineList = InitialPumpMachineList(
context,
machine_id_array,//机泵ID
monitor_id_run_status_array,//运行状态
monitor_id_pump_flow_array,// 流量计
is液位代替进口压力,
monitor_id_inlet_press_array,//进口压力计
monitor_id_outlet_press_array,//出口压力
monitor_id_motor_power_array,//瞬间功率
monitor_id_motor_frequence_array,//频率
monitor_id_motor_zhuansu_array,//转速
null,//电流
out error_info);
if (_allMachineList == null)
{
IStation.LogHelper.Error(error_info);
return false ;
}
error_info = null;
return true;
}
#endregion
}
}